For steam
Non-invasive flow measurement of LNG and cryogenic fluids
The superior flow meter for LNG and cryogenic fluids
Since years FLEXIM’s unique non-invasive ultrasonic flow meters have been running in various LNG and other cryogenic applications at temperatures down to -200 °C: from 3” lines in peak shaving plants to 36" pipes for tanker off-loading to storage tanks.
The non-invasive ultrasonic flow meters provide the ideal solution for all cases where reliable and trouble-free flow measurement of cryogenic fluids is required. With its huge measurement range FLUXUS Cryo is ideally suited to cover the highest flow rates of loading / off-loading processes as well as very low flow rates at start or stop of operation.
As the system measures from outside the pipe wall, installation does not require any pipe cutting or extensive pipe works. Further, FLUXUS Cryo is virtually maintenance free, does not cause any pressure drops and can never be the source for potential leaks.
With its unrivalled accuracy and reliability, FLUXUS Cryo meets all requirements for regular monitoring, control as well as SIS purposes. The implemented diagnostics can be used to detect beginning and end of the cryogenic liquid flows in batch processing.
Features
• Highly accurate flow measurement of LNG, Liquid Ethane, Liquid Air, Nitrogen and Oxygen without any pressure drops
• Highly reliable
- Maintenance-free. No moving or vibrating parts
- Dual-beam redundant measurements
• Operationally safe
- No gaskets, No leakage points
• Economic
- No pipework modification necessary
- One-man-installation without the need for lifting gear
- No pressure loss - no chance for flashing
Advantages
Retrofit Applications
• No pipework necessary
• No lifting gear required – independent of pipe size
• FLUXUS Cryo can be mounted at limited space conditions, e.g. at FLNG loading arms
• Installation is done within a few hours when the pipe is not cooled down
• The measuring system is fully integrated into the insulation
New Plants
• Highly cost-effective - only standard piping needs to be planned – FLUXUS Cryo fits
• Late design changes aren‘t a problem! One equipment type fits many pipe sizes
• No pressure-loss and thus no energy loss
• No chance to cause flashing
• Significantly reduced CAPEX, especially for large diameters
• Global installation and support by FLEXIM
Applications
• Oil & Gas
- Oil & Gas Storage and Distribution
Technical Facts
Flow channels | 1 ( optional 2) |
Quantities of measurement | Volume flow, mass flow, flow velocity |
Medium | Cryogenic Fluids (LNG, Liquid Ethane, Liquid Air, Nitrogen, Oxygen and others) |
Flow velocity range | 0.01m/s ... 25 m/s |
Measurement accuracy (standard) | ±1.2% of reading, ±0.01 m/s |
Measurement accuracy (field calibrated) | ±0.5% of reading, ±0.01 m/s |
Repeatability | ±0.15% of reading, ±0.01 m/s |
Media temperature | -200°C ... +80°C |
Operating temperature of the transmitter | -40°C ... +60°C |
Pipe diameter range | 70 mm to 1000 mm |
Degree of protection | Transmitter: IP66, Transducers: up to IP68 |
Available Hazardous Area Classification (optional) | ATEX / IECEx Zone 1 / 2; FM Class I, Div. 1 / 2 |
Communication Protocol | HART, Modbus RTU/TCP, RS485, Profibus PA, Foundation Fieldbus |
Inputs | Depending on Transmitter: Up to 4 Inputs (temperature Pt100/Pt1000), current, voltage, binary |
Outputs | Depending on Transmitter: Up to 4 Outputs: (active/passive) current, voltage, frequency, binary |